Milwaukee Instruments pH600 pH Tester

Milwaukee PH600 pH Tester
Milwaukee PH600 pH Tester
Item# Mil-PH600_meter-only
List: $27.00
Sale: $22.50

User Instruction Manual

Milwaukee Instruments pH600 pH Tester, Meter, pH600AQ pH 600

pH TESTER WITH 1 POINT MANUAL CALIBRATION, ± 0.2 pH ACCURACY, RANGE: 0.0 to 14.0 pH. 700 HOURS BATTERY LIFE – 30 DAY MILWAUKEE WARRANTY – USE CALIBRATION SOLUTION M10007B pH 7.01.

Milwaukee pH/ORP Meter Maintenance and Storage: To prolong the life of the electrode, place a small, clean sponge or tissue in the bottom of the cap, and pour some electrode storage solution (or pH 4 buffer) into the cap. After each use, always rinse the probe with water, clean it with Milwaukee MA9016 electrode cleaning solution and store the probe with Milwaukee MA9015 electrode storage solution. Never let probe dry and Never use distilled/deionized water for storage purposes. eseasongear

Accessories

Spare 1.5 V Battery for Pocket Tester, Pack/10
Spare 1.5 V Battery for eSseasongear, HANNA, HM Digital and Milwaukee Pocket pH TDS ORP Testers, Pack/10

Replacement button battery batteries for Pen style Tester Meter, SALT-3000, SALT-3050, TDS-EZ, ZT-2, TDS-3, TDS-4, COM-80, PH-80 and many more.
$3.99
Spare 1.5 V Battery for Pocket Tester, Pack/10 TQ-AG13-10X
Milwaukee M10007 pH 7.01 Buffer Solution, 20ml
Milwaukee Instruments M10007 pH 7.01 Buffer Calibration Solution, 20ml sachet, M 10007 M10007B M1007
$2.50
Milwaukee M10007 pH 7.01 Buffer Solution, 20ml Mil-M10007_1x20ml
Milwaukee Instrum. Suggested Solutions for pH Meters / Controllers
Suggested Solutions for pH Meters / Controllers

1. MA9015 storage solution for pH probe storage.

2. MA9016 cleaning solution for pH probe cleaning.

3. MA9007 pH 7 buffer for 1-point pH calibration.

4. MA9004 pH 4 and MA9010 pH 10 for 2-point pH calibration.

After each use, always rinse the probe with water, clean it with MA9016 cleaning solution and store the probe with MA9015 storage solution.

For probe cleaning - Soak it in MA9016 cleaning solution for about 3 minutes once a day or at least once a week to prevent clogging and to maintain accuracy.

For probe storage - Place a sponge or tissue in the bottom of the cap, and pour some MA9015 storage solution into the cap.

Never let probe dry after conditioning and Never use distilled/deionized water for storage purposes.

Always rinse the pH electrode with water between calibrations and testings.

Check out the "pH Electrode Care" for more details.